Platform code5900040
Platform nameAPEX Profiling Float
DescriptionArgo AUSTRALIA
Ascending Profiling Time6.94
Calib Rt Coefficienta1=1, a0=0.0024
Calib Rt CommentReal-time salinity adjustment
Calib Rt Date20111208000000
Calib Rt EquationPSAL_ADJUSTED = a1 * PSAL + a0
Calib Rt ParameterPSAL
Cycle Time240
Data CentreCS
Deepest Pressure2000
Deploy PlatformUMITAKE_MARU
DirectionA
End Mission Date05/07/2012 14:03:33
End Mission StatusT
Inst Reference620
LABEL ENCTD_PRES
LABEL ENCTD_TEMP
LABEL ENCTD_CNDC
LABEL ENFLOAT
Launch Qc1
ParameterTEMP
ParameterPSAL
ParameterPRES
Parameter Accuracy0.002
Parameter Accuracy0.005
Parameter Accuracy2.4
Parameter Resolution0.001
Parameter Resolution0.001
Parameter Resolution0.1
Parameter Unitsdecibars
Parameter Unitspsu
Parameter Unitsdeg C
Parking Pressure2000
Parking Time224.88
Pf Status CodeN
Pi NameSusan Wijffels
Platform MakerWRC
Platform ModelAPEX-SBE
Positioning SystemARGOS
Pr Cycle Period 110
Pr Experiment IdArgo Australia
Pr Launch Datetime24/01/2003 17:50:00
Pr Launch Latitude-37.99
Pr Launch Longitude110.002
Pr Probe Code846
Predeployment Calib Coefficientser# = 726 temperature coeffs: A0 = -0.0000 A1 = 0.0003 A2 = -0.0000 A3 = 0.0000
Predeployment Calib Coefficientser# = 726 conductivity coeffs: G = -0.1541 H = 0.1541 I = -0.0002 J = 0.0000 CPCOR = -0.0000 CTCOR = 0.0000 WBOTC = 0.0000
Predeployment Calib Coefficientser# = 726 pressure coeffs: PA0 = -1.3002 PA1 = 0.14152 PA2 = 1.5514e-08 PTCA0 = 56.5967 PTCA1 = -0.054429 PTCA2 = 1.2521e-05 PTCB0 = -61.8002 PTCB1 = -0.68342 PTCB2 = 0.011893 PTHA0 = 100.1881 PTHA1 = 0.012643 PTHA2 = -0.00018275
Predeployment Calib EquationTemperature ITS-90 = 1/ { a0 + a1[lambda nu (n)] + a2 [lambda nu^2 (n)] + a3 [lambda nu^3 (n)]} - 273.15 (deg C)
Predeployment Calib Equationy=thermistor output; t=PTHA0+PTHA1*y+PTHA2*y^2; x=pressure output-PTCA0+PTCA1*t+PTCA2*t^2; n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2); pressure (psia)=PA0+PA1*n+PA2*n^2
Predeployment Calib Equationf = inst freq * sqrt(1.0 + WBOTC * t) / 1000.0; t = temperature [deg C]; p = pressure [decibars]; delta = CTcor; epsilon = CPcor; Conductivity = (g + hf^2 + if^3 + jf^4)/(1+ delta t + epsilon p) Siemens/meter
Project NameArgo Australia
Ptt6488
Repetition Rate1
SensorCTD_CNDC
SensorCTD_TEMP
SensorCTD_PRES
Sensor Accuracy0.005
Sensor Accuracy2.4
Sensor Accuracy0.002
Sensor MakerSBE
Sensor MakerSBE
Sensor MakerAMETEK
Sensor ModelSBE41
Sensor ModelAMETEK
Sensor ModelSBE41
Sensor Resolution0.0001
Sensor Resolution1e-05
Sensor Resolution0.02
Sensor Serial No726
Sensor Serial No726
Sensor Serial No2657730019
Sensor UnitsSiemens/meter
Sensor Unitsdecibars
Sensor Unitsdeg C
Start Date03/02/2003 15:36:36
Start Date Qc1
Surface Time8.06
Trans Frequency401.65 x 10^6
Trans Repetition45
Trans SystemARGOS
Trans System Id02039
Eulerian networksMyOcean eulerian platforms
Available dataFrom 02/02/2003 to 04/07/2012
Selected data

From ... to ... Refresh

Filters

Download time seriesTo download data, please login here
Download vertical profilesTo download data, please login here
Physical parametersNo valid measure for this period
Waterfall profiles