Platform code5900032
Platform nameAPEX Profiling Float
DescriptionArgo AUSTRALIA
Ascending Profiling Time6.94
Calib Rt Coefficienta1=1, a0=0.0028
Calib Rt CommentReal-time salinity adjustment
Calib Rt Date20110226000000
Calib Rt EquationPSAL_ADJUSTED = a1 * PSAL + a0
Calib Rt ParameterPSAL
Cycle Time240
Data CentreCS
Deepest Pressure2000
Deploy PlatformBBC_Nordland
DirectionA
End Mission Date26/02/2011 11:54:30
End Mission StatusT
Inst Reference575
LABEL ENCTD_PRES
LABEL ENCTD_TEMP
LABEL ENCTD_CNDC
LABEL ENFLOAT
Launch Qc1
ParameterTEMP
ParameterPSAL
ParameterPRES
Parameter Accuracy0.002
Parameter Accuracy0.005
Parameter Accuracy2.4
Parameter Resolution0.001
Parameter Resolution0.001
Parameter Resolution0.1
Parameter Unitsdecibars
Parameter Unitspsu
Parameter Unitsdeg C
Parking Pressure2000
Parking Time222.96
Pf Status CodeN
Pi NameSusan Wijffels
Platform MakerWRC
Platform ModelAPEX-SBE
Positioning SystemARGOS
Pr Cycle Period 110
Pr Experiment IdArgo Australia
Pr Launch Datetime01/10/2002 16:49:00
Pr Launch Latitude-10.94
Pr Launch Longitude103
Pr Probe Code846
Predeployment Calib Coefficientser# = 624 temperature coeffs: A0 = -0.0001 A1 = 0.0003 A2 = -0.0000 A3 = 0.0000
Predeployment Calib Coefficientser# = 624 conductivity coeffs: G = -1.0440 H = 0.1581 I = -0.0003 J = 0.0000 CPCOR = -0.0000 CTCOR = 0.0000 WBOTC = 0.0000
Predeployment Calib Coefficientser# = 624 pressure coeffs: PA0 = -1.6586 PA1 = 0.14144 PA2 = 6.2616e-09 PTCA0 = 56.4661 PTCA1 = -0.054772 PTCA2 = 1.2736e-05 PTCB0 = 18.2929 PTCB1 = -0.33861 PTCB2 = -1.0732 PTHA0 = 100.4608 PTHA1 = 0.0094266 PTHA2 = -0.00020233
Predeployment Calib EquationTemperature ITS-90 = 1/ { a0 + a1[lambda nu (n)] + a2 [lambda nu^2 (n)] + a3 [lambda nu^3 (n)]} - 273.15 (deg C)
Predeployment Calib Equationy=thermistor output; t=PTHA0+PTHA1*y+PTHA2*y^2; x=pressure output-PTCA0+PTCA1*t+PTCA2*t^2; n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2); pressure (psia)=PA0+PA1*n+PA2*n^2
Predeployment Calib Equationf = inst freq * sqrt(1.0 + WBOTC * t) / 1000.0; t = temperature [deg C]; p = pressure [decibars]; delta = CTcor; epsilon = CPcor; Conductivity = (g + hf^2 + if^3 + jf^4)/(1+ delta t + epsilon p) Siemens/meter
Project NameArgo Australia
Ptt6302
Repetition Rate1
SensorCTD_CNDC
SensorCTD_TEMP
SensorCTD_PRES
Sensor Accuracy0.005
Sensor Accuracy2.4
Sensor Accuracy0.002
Sensor MakerSBE
Sensor MakerSBE
Sensor MakerAMETEK
Sensor ModelSBE41
Sensor ModelAMETEK
Sensor ModelSBE41
Sensor Resolution0.0003
Sensor Resolution2e-05
Sensor Resolution0.03
Sensor Serial No624
Sensor Serial No624
Sensor Serial No2657718057
Sensor UnitsSiemens/meter
Sensor Unitsdecibars
Sensor Unitsdeg C
Start Date11/10/2002 11:38:16
Start Date Qc1
Surface Time10.05
Trans Frequency401.65 x 10^6
Trans Repetition45
Trans SystemARGOS
Trans System Id02039
Eulerian networksMyOcean eulerian platforms
Available dataFrom 10/10/2002 to 25/02/2011
Selected data

From ... to ... Refresh

Filters

Download time seriesTo download data, please login here
Download vertical profilesTo download data, please login here
Physical parametersNo valid measure for this period
Waterfall profiles