Platform code5900027
Platform nameAPEX Profiling Float
DescriptionArgo AUSTRALIA
Ascending Profiling Time5.03
Calib Rt Coefficienta1=1, a0=0.0018
Calib Rt CommentReal-time salinity adjustment
Calib Rt Date20121025000000
Calib Rt EquationPSAL_ADJUSTED = a1 * PSAL + a0
Calib Rt ParameterPSAL
Cycle Time240
Data CentreCS
Deepest Pressure1450
Deploy PlatformCEC_Pacific
DirectionA
End Mission Date25/10/2012 15:03:08
End Mission StatusT
Inst Reference574
LABEL ENCTD_PRES
LABEL ENCTD_TEMP
LABEL ENCTD_CNDC
LABEL ENFLOAT
Launch Qc1
ParameterTEMP
ParameterPSAL
ParameterPRES
Parameter Accuracy0.002
Parameter Accuracy0.005
Parameter Accuracy2.4
Parameter Resolution0.001
Parameter Resolution0.001
Parameter Resolution0.1
Parameter Unitsdecibars
Parameter Unitspsu
Parameter Unitsdeg C
Parking Pressure1450
Parking Time222.96
Pf Status CodeN
Pi NameSusan Wijffels
Platform MakerWRC
Platform ModelAPEX-SBE
Positioning SystemARGOS
Pr Cycle Period 110
Pr Experiment IdArgo Australia
Pr Launch Datetime18/09/2002 23:07:00
Pr Launch Latitude-9.18
Pr Launch Longitude111.997
Pr Probe Code846
Predeployment Calib Coefficientser# = 622 temperature coeffs: A0 = -0.0000 A1 = 0.0003 A2 = -0.0000 A3 = 0.0000
Predeployment Calib Coefficientser# = 622 conductivity coeffs: G = -1.0339 H = 0.1593 I = -0.0003 J = 0.0000 CPCOR = -0.0000 CTCOR = 0.0000 WBOTC = 0.0000
Predeployment Calib Coefficientser# = 622 pressure coeffs: PA0 = 1.3827 PA1 = 0.14144 PA2 = 6.9312e-09 PTCA0 = 56.2568 PTCA1 = -0.053972 PTCA2 = 1.2346e-05 PTCB0 = 106.7148 PTCB1 = 1.1187 PTCB2 = -0.03106 PTHA0 = 100.4803 PTHA1 = 0.0093374 PTHA2 = -0.00019802
Predeployment Calib EquationTemperature ITS-90 = 1/ { a0 + a1[lambda nu (n)] + a2 [lambda nu^2 (n)] + a3 [lambda nu^3 (n)]} - 273.15 (deg C)
Predeployment Calib Equationy=thermistor output; t=PTHA0+PTHA1*y+PTHA2*y^2; x=pressure output-PTCA0+PTCA1*t+PTCA2*t^2; n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2); pressure (psia)=PA0+PA1*n+PA2*n^2
Predeployment Calib Equationf = inst freq * sqrt(1.0 + WBOTC * t) / 1000.0; t = temperature [deg C]; p = pressure [decibars]; delta = CTcor; epsilon = CPcor; Conductivity = (g + hf^2 + if^3 + jf^4)/(1+ delta t + epsilon p) Siemens/meter
Project NameArgo Australia
Ptt6301
Repetition Rate1
SensorCTD_CNDC
SensorCTD_TEMP
SensorCTD_PRES
Sensor Accuracy0.005
Sensor Accuracy2.4
Sensor Accuracy0.002
Sensor MakerSBE
Sensor MakerSBE
Sensor MakerAMETEK
Sensor ModelSBE41
Sensor ModelAMETEK
Sensor ModelSBE41
Sensor Resolution0.0001
Sensor Resolution3e-05
Sensor Resolution0.02
Sensor Serial No622
Sensor Serial No622
Sensor Serial No2657718087
Sensor UnitsSiemens/meter
Sensor Unitsdecibars
Sensor Unitsdeg C
Start Date28/09/2002 15:19:19
Start Date Qc1
Surface Time11.97
Trans Frequency401.65 x 10^6
Trans Repetition45
Trans SystemARGOS
Trans System Id02039
Eulerian networksMyOcean eulerian platforms
Available dataFrom 27/09/2002 to 25/10/2012
Selected data

From ... to ... Refresh

Filters

Download time seriesTo download data, please login here
Download vertical profilesTo download data, please login here
Physical parametersNo valid measure for this period
Waterfall profiles