Platform code5900039
Platform nameAPEX Profiling Float
DescriptionArgo AUSTRALIA
Ascending Profiling Time6.94
Calib Rt Coefficienta1=1, a0=-0.0334
Calib Rt CommentReal-time salinity adjustment
Calib Rt Date20110918000000
Calib Rt EquationPSAL_ADJUSTED = a1 * PSAL + a0
Calib Rt ParameterPSAL
Cycle Time240
Data CentreCS
Deepest Pressure2000
Deploy PlatformUMITAKE_MARU
DirectionA
End Mission Date18/09/2011 13:26:22
End Mission StatusT
Inst Reference618
LABEL ENCTD_PRES
LABEL ENCTD_TEMP
LABEL ENCTD_CNDC
LABEL ENFLOAT
Launch Qc1
ParameterTEMP
ParameterPSAL
ParameterPRES
Parameter Accuracy0.002
Parameter Accuracy0.005
Parameter Accuracy2.4
Parameter Resolution0.001
Parameter Resolution0.001
Parameter Resolution0.1
Parameter Unitsdecibars
Parameter Unitspsu
Parameter Unitsdeg C
Parking Pressure2000
Parking Time224.88
Pf Status CodeN
Pi NameSusan Wijffels
Platform MakerWRC
Platform ModelAPEX-SBE
Positioning SystemARGOS
Pr Cycle Period 110
Pr Experiment IdArgo Australia
Pr Launch Datetime23/01/2003 17:58:00
Pr Launch Latitude-34.993
Pr Launch Longitude112.995
Pr Probe Code846
Predeployment Calib Coefficientser# = 724 temperature coeffs: A0 = -0.0003 A1 = 0.0004 A2 = -0.0000 A3 = 0.0000
Predeployment Calib Coefficientser# = 724 conductivity coeffs: G = -1.0571 H = 0.1504 I = -0.0002 J = 0.0000 CPCOR = -0.0000 CTCOR = 0.0000 WBOTC = 0.0000
Predeployment Calib Coefficientser# = 724 pressure coeffs: PA0 = -0.38976 PA1 = 0.14154 PA2 = 9.9619e-09 PTCA0 = 56.5617 PTCA1 = -0.054373 PTCA2 = 1.2523e-05 PTCB0 = -7.6488 PTCB1 = -0.055662 PTCB2 = -0.0084456 PTHA0 = 100.257 PTHA1 = 0.011921 PTHA2 = -0.00020012
Predeployment Calib EquationTemperature ITS-90 = 1/ { a0 + a1[lambda nu (n)] + a2 [lambda nu^2 (n)] + a3 [lambda nu^3 (n)]} - 273.15 (deg C)
Predeployment Calib Equationy=thermistor output; t=PTHA0+PTHA1*y+PTHA2*y^2; x=pressure output-PTCA0+PTCA1*t+PTCA2*t^2; n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2); pressure (psia)=PA0+PA1*n+PA2*n^2
Predeployment Calib Equationf = inst freq * sqrt(1.0 + WBOTC * t) / 1000.0; t = temperature [deg C]; p = pressure [decibars]; delta = CTcor; epsilon = CPcor; Conductivity = (g + hf^2 + if^3 + jf^4)/(1+ delta t + epsilon p) Siemens/meter
Project NameArgo Australia
Ptt6448
Repetition Rate1
SensorCTD_CNDC
SensorCTD_TEMP
SensorCTD_PRES
Sensor Accuracy0.005
Sensor Accuracy2.4
Sensor Accuracy0.002
Sensor MakerSBE
Sensor MakerSBE
Sensor MakerAMETEK
Sensor ModelSBE41
Sensor ModelAMETEK
Sensor ModelSBE41
Sensor Resolution0.0001
Sensor Resolution1e-05
Sensor Resolution0.02
Sensor Serial No724
Sensor Serial No724
Sensor Serial No2657730015
Sensor UnitsSiemens/meter
Sensor Unitsdecibars
Sensor Unitsdeg C
Start Date02/02/2003 13:43:44
Start Date Qc1
Surface Time8.06
Trans Frequency401.65 x 10^6
Trans Repetition45
Trans SystemARGOS
Trans System Id02039
Eulerian networksMyOcean eulerian platforms
Available dataFrom 01/02/2003 to 17/09/2011
Selected data

From ... to ... Refresh

Filters

Download time seriesTo download data, please login here
Download vertical profilesTo download data, please login here
Physical parametersNo valid measure for this period
Waterfall profiles