Platform code5900034
Platform nameAPEX Profiling Float
DescriptionArgo AUSTRALIA
Ascending Profiling Time6.25
Calib Rt Coefficienta1=1, a0=-0.0326
Calib Rt CommentReal-time salinity adjustment
Calib Rt Date20120131000000
Calib Rt EquationPSAL_ADJUSTED = a1 * PSAL + a0
Calib Rt ParameterPSAL
Cycle Time240
Data CentreCS
Deepest Pressure1800
Deploy PlatformIsabella_G
DirectionA
End Mission Date31/01/2012 20:31:22
End Mission StatusT
Inst Reference576
LABEL ENCTD_PRES
LABEL ENCTD_TEMP
LABEL ENCTD_CNDC
LABEL ENFLOAT
Launch Qc1
ParameterTEMP
ParameterPSAL
ParameterPRES
Parameter Accuracy0.002
Parameter Accuracy0.005
Parameter Accuracy2.4
Parameter Resolution0.001
Parameter Resolution0.001
Parameter Resolution0.1
Parameter Unitsdecibars
Parameter Unitspsu
Parameter Unitsdeg C
Parking Pressure1800
Parking Time222.96
Pf Status CodeN
Pi NameSusan Wijffels
Platform MakerWRC
Platform ModelAPEX-SBE
Positioning SystemARGOS
Pr Cycle Period 110
Pr Experiment IdArgo Australia
Pr Launch Datetime09/12/2002 19:46:31
Pr Launch Latitude-12
Pr Launch Longitude109.336
Pr Probe Code846
Predeployment Calib Coefficientser# = 628 temperature coeffs: A0 = -0.0002 A1 = 0.0003 A2 = -0.0000 A3 = 0.0000
Predeployment Calib Coefficientser# = 628 conductivity coeffs: G = -1.0680 H = 0.1594 I = -0.0003 J = 0.0000 CPCOR = -0.0000 CTCOR = 0.0000 WBOTC = 0.0000
Predeployment Calib Coefficientser# = 628 pressure coeffs: PA0 = -0.9066 PA1 = 0.14105 PA2 = 1.5691e-08 PTCA0 = 56.4081 PTCA1 = -0.054267 PTCA2 = 1.249e-05 PTCB0 = 16.4444 PTCB1 = -0.23819 PTCB2 = -0.0036844 PTHA0 = 100.5504 PTHA1 = 0.0089633 PTHA2 = -0.00015117
Predeployment Calib EquationTemperature ITS-90 = 1/ { a0 + a1[lambda nu (n)] + a2 [lambda nu^2 (n)] + a3 [lambda nu^3 (n)]} - 273.15 (deg C)
Predeployment Calib Equationy=thermistor output; t=PTHA0+PTHA1*y+PTHA2*y^2; x=pressure output-PTCA0+PTCA1*t+PTCA2*t^2; n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2); pressure (psia)=PA0+PA1*n+PA2*n^2
Predeployment Calib Equationf = inst freq * sqrt(1.0 + WBOTC * t) / 1000.0; t = temperature [deg C]; p = pressure [decibars]; delta = CTcor; epsilon = CPcor; Conductivity = (g + hf^2 + if^3 + jf^4)/(1+ delta t + epsilon p) Siemens/meter
Project NameArgo Australia
Ptt6311
Repetition Rate1
SensorCTD_CNDC
SensorCTD_TEMP
SensorCTD_PRES
Sensor Accuracy0.005
Sensor Accuracy2.4
Sensor Accuracy0.002
Sensor MakerSBE
Sensor MakerSBE
Sensor MakerAMETEK
Sensor ModelSBE41
Sensor ModelAMETEK
Sensor ModelSBE41
Sensor Resolution0.0001
Sensor Resolution2e-05
Sensor Resolution0.02
Sensor Serial No628
Sensor Serial No628
Sensor Serial No2657718134
Sensor UnitsSiemens/meter
Sensor Unitsdecibars
Sensor Unitsdeg C
Start Date09/12/2002 19:46:31
Start Date Qc1
Surface Time10.75
Trans Frequency401.65 x 10^6
Trans Repetition45
Trans SystemARGOS
Trans System Id02039
Eulerian networksMyOcean eulerian platforms
Available dataFrom 08/12/2002 to 31/01/2012
Selected data

From ... to ... Refresh

Filters

Download time seriesTo download data, please login here
Download vertical profilesTo download data, please login here
Physical parametersNo valid measure for this period
Waterfall profiles